FUJIAN BOSS ELECTRICAL MACHINERY CO.,LTD.

YOUR SATISFACTION IS OUR MISSION QUALITY IS OUR CULTURE

Manufacturer from China
Active Member
6 Years
Home / Products / Perkins Diesel Generator /

Auto Start Perkins Diesel Generator Set 60KVA Four Stroke Excellent Ventilation

Contact Now
FUJIAN BOSS ELECTRICAL MACHINERY CO.,LTD.
City:fuzhou
Province/State:fujian
Country/Region:china
Contact Person:MissLily Tang
Contact Now

Auto Start Perkins Diesel Generator Set 60KVA Four Stroke Excellent Ventilation

Ask Latest Price
Video Channel
Brand Name :BOSSPOWER
Model Number :BS-P60
Certification :CE
Place of Origin :CHINA
MOQ :1 Set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :100 Sets per Month
Delivery Time :About 30 days after receiving deposit or original L/C.
Packaging Details :Packed in Plywood Cases or Wooden Cases or Foam, etc.
Engine :PERKINS 1103A-33TG2
Alternator :Stamford UCI224E
Power :48KW / 60KVA
Output Type :AC 3 Phase
Frequency :50HZ
Speed :1500RPM
Voltage :380V 400V 480V 220V 230V 240V
Control panel :Deepsea , ComAp , Datakom
Cooling Method :Water Cooling
Starting type :Electric start
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

48kW / 60KVA Soundproof type 4 stroke Auto start perkins diesel generator set​

Generator Supply Scope :

1 . Engine , alternator , radiator , auto control panel .

2 . Base frame , base fuel tank , Flexible pipes , flange , exhaust silencer .

3 . Battery , battery charger , battery wires , internal cables , circuit breaker .

4 . Manual books of engine , alternator , genset , control panel , wires diagram .

5 . optional parts : Soundproof

6 . ATS ( automatic transfer switch ) , AMF panel , Trailer , Parallel system by your extra choose

Optional Supply :

1 . ATS ( Automatic transfer system )

2 . AMF Panel

3 . Silent canopy ( for silent type only )

4 . Fuel Tank ( 8 hours running )

5 . Four Protection ( high temperature auto shutdown , overload automatic shutdown ,

low oil pressure automatic shutdown , automatic shutdown phase )

6 . Parallel system

7 . Remote system

8 . Trailer type

9 . Soundproof / water proof

10 . Lighting tower

Soundproof (Silent ) type

1. Excellent ventilation

2. Oil tank mounted on base frame for 12 Hours working

3. Highly Corrosion Resistant construction

4. Excellent Access for Maintenance

5. Security and Safety

6. 1m<100 dB (open type) <80dB (soudproof)<70dB (silent type)<65dB (super silent)

Features of genset :

1 . Powered by heavy duty industrial diesel engines , Cummins , Perkins , Isuzu , Duetz or China brand diesel engine can be chosen.

2 . Radiator 40 degree or 50 degree max, fans are driven by belt , with safety guard .

3 . 12/24DC start motor and storage battery .

4 . Brushless , self-excited , IP22/23 , insulation H alternator .

5 . Absorber to reduce vibration .

6 . Dry type air filter , fuel filter , oil filter .

7 . Main line circuit breaker .

8 . Control system : key start control panel as standard , digital auto start or ATS system is optional .

9 . 8 hours operation base fuel tank .

10 . High efficient muffler to reduce noise .

11 . Ripple flex exhaust pipe , exhaust siphon and flange etc.

12 . Genset type: open type or soundproof/silent type, or trailer type .

13 . Maintenance and operation manual for generator , engine and alternator , engine parts catalog , quality certificate , etc .

Perkins is a famous engine manufacturer, which acquired the world’s leading brand Rolls-Royce in nineties

of last century. Since the engines produced are used in the assembly of Rolls-Royce cars, it is world-renowned.

Perkins engines have excellent stability, reliability and durability, being widely used in the communication,

industry, outdoor works, mining, the rescue, military and other fields.

PRODUCT DESCRIPTION
Genset Model BS-P60
Prime Power (kw/kva) 48/60 Standby Power(kw/kva) 53/66
Voltage (v) 400/230 Rated Speed (rpm) 1500
Frequency (Hz) 50 Rated Current (A) 86.6
Connection: 3 phase 4 wire Power Factor: 0.8
Engine Model: 1103A-33TG2 Alternator Model: UCI224E
Gross Weight (kgs)-Open 1030 Gross Weight (kgs)-Silent 1140
Dimensions (mm)-Open 1750X750X1250 Dimensions (mm)-Silent 2270X1000X1360
Engine Parameter:

Manufacturer/Model

Air Intake System

Fuel System

Cylinder numbers

Displacement

Bore x Stroke

Compression Ratio

Max. Power

Governing System

PERKINS, 1103A-33TG2, 4 stroke
Turbocharged

Rotary Fuel injection Pump,

direct injection

3 cylinders Vertical in-line

3.3L

105 x 127 mm

17.25 : 1

59.3KW / 79.5HP

Mechanical

Exhaust System

Exhaust Volume

Exhaust temperature

Max. Allowed Back Pressure

10.4m³/min

571 ℃

10 KPa

Intake System

Max. Allowed Pressure

Consumption

Air Flow

8 kPa

3.9m³/min

89.0m³/min

Fuel System

100% Load (Prime)

75% Load(Prime)

50% Load (Prime)

13.9 l/h

10.4 l/h

7.2 l/h

Lube System

Oil Capacity

Oil Consumption

Engine Oil Tank Capacity

Oil Pressure at rated speed

8.3L

≤0.021 l/h

7.8 L

276 - 414 kPa

Cooling system

Coolant Capacity

Thermostat

Max. Water Temperature

10.2L with radiator / 4.4L without radiator

82 - 93℃

110℃

Alternator Parameter: Basic Information

The alternators meet the standards of:

GB755, BS5000, VDE00530, NEMAMG1-22,IED34-1,CSA22.2 and AS1350

Technical Data:

Manufacturer:

Phases:

Connection:

Bearing numbers:

Power Factor:

Protection Class:

Altitude Condition:

Excitation:

Insulation class/Temp. rise class:

Tel. Influence Factor TIF:

Tel. Harmonic Factor THF:

Steady State Voltage Regulation:

Alternator Capacity:

Efficiency:

Cooling Air Flow:

STAMFORD,UCI224E

3

3 phase 4 wire, Y type

1

0.8

IP23

≤1000M

Brushless, self-excitation

H / H

<50

<2%

≤±1%

60KVA

88.8%

0.216m³/s

Auto Start Perkins Diesel Generator Set 60KVA Four Stroke Excellent Ventilation

Auto Start Perkins Diesel Generator Set 60KVA Four Stroke Excellent Ventilation

FAQ

Q : How to choose the power ?
A : Collect all power of your equipments , take the current into your consideration .
Q : What is the difference between Prime power and Standby power ?
A : Prime power is 12hours continous power , one hour 10% over load in every 12 running hours is allowed .
Standby power is the limit value of maximum output for emergency use . Overloading is prohibited

Q : Do you offer OEM service ?
A : Yes

Q : What is your payment term ?
A : 30% T/T in advance , the rest payment before shipment . Or irrevocable L/C .
Q : What is your lead time ?
A : About 30 days after receiving deposit or original L/C . But if your order with some special design , then the delivery time is longer .

Inquiry Cart 0